Diesel heater error codes E-01 to E-10
This is the common LCD controller table used by most Chinese-made diesel air heaters. VEVOR controllers fold both voltage faults into E-02 (pick VEVOR in the finder above). Some controllers and older firmware use different numbers, so if a meaning below does not match what your heater is doing, check the card or manual that came with your controller.
| Code | What it means | Fix, in order |
|---|---|---|
| E-01 | Supply voltage too high The control board measured more voltage than it accepts. On most 12 V heaters the trip point is roughly 16 V, on 24 V heaters about 32 V. |
|
| E-02 | Supply voltage too low The voltage dropped below the minimum, usually during the start when the glow plug pulls its highest current. VEVOR manuals ask for at least 10 V and 15 A on 12 V supplies. |
|
| E-03 | Glow plug (ignition plug) fault The board found the glow plug open-circuit, shorted or drawing the wrong current. |
|
| E-04 | Fuel pump fault The board sees an open or short circuit on the fuel (dosing) pump line. |
|
| E-05 | Overheating The heat exchanger is too hot. VEVOR's manual gives about 280 °C on the aluminium body as the protection point. |
|
| E-06 | Fan motor fault The board cannot see the blower turning at the speed it expects. |
|
| E-07 | Controller not connected The control panel and the heater's main board have stopped talking to each other. |
|
| E-08 | Flame went out (or repeated start failure) The heater lit, then lost the flame, or failed to restart after a flame-out. |
|
| E-09 | Temperature sensor fault The board is getting no sensible reading from a temperature sensor. |
|
| E-10 | Failed to ignite The heater tried to start but never detected a flame. |
|
Method
How this works
Most diesel air heaters sold online use one of a few control boards, and their LCD controllers show a fault as E- followed by a number. The finder uses the common table printed on the controller card of most of these heaters, and VEVOR's own manual table, which merges both voltage faults into E-02.
The causes are ordered by how often they turn out to be the problem and how cheap they are to check: fuel, voltage and air first, parts last. Before replacing anything, clear the code (switch off, wait for the fan to stop, start again) and see whether it comes back.
Branded heaters such as Webasto, Eberspacher, Espar, Planar and Autoterm use their own fault lists and flash codes. Use their manuals or a dealer's diagnostic tool for those.
Questions
Asked often
What does E-08 mean on a diesel heater?
On most Chinese LCD controllers E-08 means the flame went out after lighting, or the heater failed to restart after losing its flame. The usual causes are fuel starvation (low tank, air in the line, a clogged filter), a blocked intake or exhaust, or running at a very low setting.
What does E-10 mean on a diesel heater?
E-10 is a failed ignition: the heater tried to start and never detected a flame. Check the fuel supply and priming first, then the voltage during the start, then the intake and exhaust, and finally carbon on the glow-plug screen.
How do I reset a diesel heater error code?
Switch the heater off at the controller and let the fan finish its cool-down, then switch it on again. If the code returns, the fault is still there; work through the causes for that code.
Why does my VEVOR heater show E-02?
VEVOR uses E-02 for any supply-voltage or current problem, low or high. Check the battery charge, the cable size and every connection, and avoid powering the heater from a cigarette-lighter socket.